1200° C LGO Box Furnaces
 
Versatile LGO Series Box Furnaces feature the latest technical advances in heating elements, insulation and temperature control, all integrated into a self-contained cabinet. The patented LGOä heating element (light gauge overbend) delivers maximum radiant heat energy to the process load. The LGOä element is imbedded within Lindberg/Blue M's exclusive Moldathermâ insulation, combined with unique double shell construction to provide optimum temperature uniformity, energy efficiency, fast response, quick heat-up and rapid cool-down.

General Features
  • Patented LGO (light gauge overbend) heating elements with Moldathermâ insulation for efficient and economical transfer of heat to chamber, with low exterior temperatures
  • Variable heat-up rate eliminates thermal shock to materials with quick heat-up and cool-down rates
  • Choice of side hinge or vertical lift door; see specifications for model selection
  • Air vent (1" dia., top) and air inlet (.375" dia., rear) for inert atmosphere exchange
  • Self-tuning, digital instrumentation for precise temperature setpoint and display; automatically sets best control parameter values during operation
  • Platinel II ® thermocouple for long-term stability
  • Main power on/off switch on control panel; control panel designed for easy maintenance access
  • Safety door switch to interrupt power to heating element when door is opened; protects heating elements and minimizes exposure to end-user
  • Removable shelves for versatility; 0.58 cu.ft. models include 1 two-part shelf, center position; 1.95 cu.ft. models have 3 shelf positions; 1 two-part shelf included standard
  • Moldathermâ hearthplate supports loadand prevents damage due to spillage

Digital, Single Setpoint Controller

  • Microprocessor-based self-tuning PID control (proportional, integral, derivative) provides optimum thermal process, prevents overshoot
  • Single segment, single setpoint, 1 ramp to setpoint
  • Adjustable high limit overtemperature protection
  • Simultaneous LED display of actual temperature vs. setpoint
  • May be configured to display temperature in either °C or °F 

Digital 16 Segment, (1) Program Programmable Controller

  • Microprocessor-based self-tuning PID control (proportional, integral, derivative) provides optimum thermal process, prevents overshoot 16 segments, 1 program with 8 ramps (up and down) and 8 dwells (timed holds)
  • Adjustable high limit overtemperature protection
  • Simultaneous LED display of actual temperature vs. setpoint
  • May be configured to display temperature in either °C or °F

Digital 16 Segment, (4) Program Programmable Controller

  • Available on models with "P" designation
  • Microprocessor-based self-tuning PID control (proportional, integral, derivative) provides optimum thermal process, prevents overshoot
  • 16 segments, 4 programs with 8 ramps (up and down) and 8 dwells (timed holds) eachAdjustable high limit overtemperature protection
  • Simultaneous LED display of actual temperature vs. setpoint
  • May be configured to display temperature in either °C or °F

Overtemperature Control (OTC)

  • Adjustable digital overtemperature control, available on selected models with "B" designation; see chart
  • Protects furnace and load in the event of primary control circuit failure
  • Overrides main controller, assumes temperature control and shuts off power to furnace if high limit is reached
  • Manual re-set required for safety
  • Operates via magnetic contacts through signal from independent thermocouple 

Flowmeter Option (FM) (Inert Atmosphere Only)

  • Available on selected models with ÒFM" designation; see chart
  • Gas flowmeter, adjustable, located on front control panel
  • Adjustable flow rate, range 1.0 to 10.0 cu.ft./hr standard
  • Suitable for inert gas or air flow to chamber
  • Allows fresh air exchange for ashing applications
  • Not suitable for combustible or volatile gases.

    Note: Use with inert atmosphere will exhibit some leakage.

Specifications

1200°C LGO™ Box Furnaces
Vertical Lift Door, 0.6 cu ft (16.4 liters),
Temperature Range  1200°C

Model Electrical
Volts, Hz, 1Ø
Watts Interior Dimensions
W X F-B X H in" (cm)
Exterior Dimensions
W X F-B X H in" (cm)
BF51731C 208/240V,
50/60Hz
4500 13"(33)x11"(27.9)x 7"(17.8) 24"(61)x23"(58.4) x27"(68.6)

Horizontal Side Swing Door, 2.0 cu ft (55.3 liters),
Temperature Range 100°C to 1200°C

Model Electrical
Volts, Hz, 1Ø
Watts Interior Dimensions
W X F-B X H in" (cm)
Exterior Dimensions
W X F-B X H in" (cm)
BF51841C 208/240V,
50/60Hz
5800 15"(38.1)x15"(38.1) x15"(38.1) 29"(73.6)x28"(71.1)x 33"(83.8)

Web Site designed and Maintained by Web Site Publishers, Inc.©